| Conductor | Insulation | |
| Stranded bare copper wire 0,13mm; nom. 0,25mm² – AWG24; nominal diameter 0,65mm Lay agree with UL 758 tab 5,9; conform to EN 13602 – ETP1, DIN 40500 E-Cu 58 | Polyolefin compound; nominal diameter 1,2mm | |
| Core Identification | Assembly | |
| Colour cores: blue – black – brown – white | Four cores stranded together | |
| Sheath | Electrical | |
| Outer sheath: PUR (ether base), 90 ShA; diameter 4,3 ±0,20mm; conform to UL AWM Style 20549 Colour: black similar RAL 9005 | Operating voltage: 300 Vrms Test voltage: 2000 Vac Conductor resistance: 78,4 Ω/Km (IEC 60344) | |
| Temperature | Bending Radius | |
| Operating temperature range, fixed: -40 °C to +80 °C Operating temperature range, flex: -25 °C to +80 °C | Bending radius, fixed: 7,5 x Ø Bending radius, flex: 10 x Ø | |
| Movement Data | Flame | |
| Speed: 120 m/min Acceleration: 5 m/sec² | UL Horizontal flame test / CSA FT2 / IEC 60332-2-2 | |
| Approval | ||
| Oil-resistant: ISO 6722 UV-resistant: UL 1581 / 2556 – 300h Halogen-free: CEI EN 60754-1 / VDE 0482-754-1 Silicone, Pb, Cd, Hg, FCKW free: yes |