SS3X2X0,14+2X0,34

0.00

SKU: SS3X2X0,14+2X0,34 Category:
3x2xAWG26 2xAWG22
Conductor: stranded bare copper wire; nom. 0,14mm² – AWG26/7; nominal diameter 0,48mm; Lay agree with UL 758 tab 5,9; conform to EN 13602 – ETP1, DIN 40500 E-Cu 58

Insulation: polyolefin; nominal diameter 1,00mm

Core Identification: white-brown – green-yellow – grey-pink; acc. to DIN 47100

Assembly: six cores twisted in three pairs with appropriate lay
Conductor: stranded bare copper wire; nom. 0,34mm² – AWG22/19; nominal diameter 0,75mm. Lay agree with UL 758 tab 5,9; conform to EN 13602 – ETP1, DIN 40500 E-Cu 58

Insulation: polyolefin; nominal diameter 1,15mm

Core Identification: red – blue; conform to UL 758
Assembly Screen
3x2xAWG26 + 2xAWG22 with appropriate lay; fibrous filler can be used for a better roundnessFirst: Al/PET tape (aluminium face outside); optical coverage 100%
Second: braid type; tin copper wire 0,10mm; nominal optical coverage 85%
Protective Tape Sheath
Tape over braid screenOuter sheath: PUR (11Y), ether base; 90 ShA; diameter 6,80 ±0,20mm
Colour: green similar RAL 6018 (matt finish); conform to UL AWM Style 20233
Electrical Temperature
Operating voltage: 300 V
Test voltage: 2000 V x 1min
Conductor resistance (AWG26): 150,3 Ω/Km (IEC 60344)
Conductor resistance (AWG22): 60,6 Ω/Km (IEC 60344)
Insulation resistance: ≥2 GΩxKm
Operating temperature range, fixed: -40 °C to +80 °C
Operating temperature range, flex: -20 °C to +80 °C
Bending Radius Movement Data
Bending radius, flex: 10 x ØRecommended speed: <200 m/min (up to 300 m/min)
Recommended acceleration: <3 m/sec² (up to 30 m/sec²)
FlameApproval
UL Cable flame test; CSA FT1; IEC 60332-1-2Oil-resistant: UL 758
UV-resistant: UL 1581
Halogen-free: CEI EN 60754-1 / VDE 0482-754-1
Microbe-resistant: yes
Hydrolysis resistant: EN 50396
Hydraulic fluid, coolant emulsifier, alkali: resistant to a large extent
Cable suitable for drag chain use
Code

SS3X2X0,14+2X0,34

Cable Type

3 x 2 x 0,14 + 2 x 0,34

Ø mm

6,8

Tolerance