| Conductor | Insulation | |
| Stranded tin copper wire (Class 6); nom. 0,25mm² – AWG24; nominal diameter 0,65mm; VDE 0295 Lay agree with UL 758 tab 5,9; conform to EN 13602 – ETP1, DIN 40500 E-Cu 58 | Polyolefin compound; nominal diameter 1,15mm | |
| Core Identification | Assembly | |
| Colour cores acc. to DIN 47100 | Pairs: ten cores twisted in five pairs Total: five pairs stranded together around a central filler | |
| Screen | Protective Tape | |
| Braid type; tin copper wire; nominal optical coverage 85% | First: tape over total assembly Screen: tape over total screen | |
| Sheath | Electrical | |
| Outer sheath: PUR (ether base), 90 ShA; diameter 7,90 ±0.30mm Colour: green similar RAL 6018; conform to UL Style 20233 | Rating voltage: 300 Vrms Test voltage C/C: 2000 Vac Electric resistance: 89,8 Ω/Km (IEC 60344) | |
| Temperature | Bending Radius | |
| Operating temperature range, fixed: -40 °C to +80 °C Operating temperature range, flex: -25 °C to +80 °C | Bending radius, fixed: 5 x Ø Bending radius, flex: 7,5 x Ø | |
| Movement Data | Flame | |
| Speed: 300 m/min Acceleration: 50 m/sec² Bending cycles: 5 Mio (10 Mio bends) | UL Cable Flame Test; CSA FT1; IEC 60332-1-2 | |
| Approval | ||