Conductor Insulation
Stranded tin copper wire 0,13mm; nom. 0,08mm² – AWG28; nominal diameter 0,40mm
Lay agree with UL 758 tab 5,9; conform to EN 13602 – ETP1, DIN 40500 E-Cu 58
Polyolefin; nominal diameter 0,60mm
Core Identification Assembly
Colour cores: 5 x white – 5 x brown – 2 x yellow – 2 x green – 2 x red – 2 x violet – 2 x bluePairs: twenty cores twisted in ten pairs
Total 8x2x28AWG stranded together around 2x2x28AWG pairs
Screen Protective Tape
Braid type; tin copper wire 0,10mm; nominal optical coverage 85%
DW: stranded tin copper wire 0,16mm; 0,14mm² / 26AWG; under braid screen
First: tape over total assembly
Second: tape over total screen
Sheath Electrical
Outer sheath: PUR (ether base); 92 ShA; diameter 6,00 ±0,2mm
Colour: violet similar RAL 4001; conform to UL Style 20236
Rating voltage: 30 Vrms
Test voltage C/C: 700 Vac
Electric resistance: 235 Ω/Km (IEC 60344)
Temperature Bending Radius
Operating temperature range, fixed: -40 °C to +80 °C
Operating temperature range, flex: -20 °C to +80 °C
Bending radius, fixed: 5 x Ø
Bending radius, flex: 10 x Ø
Movement Data Flame
Speed: 180 m/min
Acceleration: 7 m/sec²
Bending cycles: 10 Mio (20 Mio stroke)
UL Cable Flame Test; CSA FT1; IEC 60332-1-2
Approval
Oil-resistant: UL 758 (OIL RES I – 100°C x 96h IRM902)
UV-resistant: UL 1581
Halogen-free: CEI EN 60754-1 / VDE 0482-754-1
FCKW, Silicone and Pb free: yes
Code

SS10X2X0,08

Cable Type

10 x 2 x 0,08

Ø mm

6,0

Tolerance

±0,20 mm