4xAWG21 | 1x2xAWG26 | |
Conductor: stranded bare copper wire 0,15mm; nom. 0,5mm² – AWG21; nominal diameter 0,95mm. Lay agree with UL 758 tab 5,9; conform to EN 13602 – ETP1, DIN 40500 E-Cu 58 ⇂ Insulation: polyolefin compound; nominal diameter 1,7mm ⇂ Core Identification: black printed (U/L1/C/L+) – (V/L2) – (W/L3/D/L-) + green/yellow |
Conductor: stranded bare copper wire 0,10mm; nom. 0,15mm² – AWG26; nominal diameter 0,50mm. Lay agree with UL 758 tab 5,9; conform to EN 13602 – ETP1, DIN 40500 E-Cu 58 ⇂ Insulation: foam polyolefin compound; nominal diameter 1,3mm ⇂ Core Identification: white – blue ⇂ Assembly: two cores twisted with solid filler in gap ⇂ Screen: braid type; tin copper wire; nominal optical coverage 85% + bi-aluminized; nonwovens tape over braid screen ⇂ Protective Tape: tape over assembly + tape over tape screen ⇂ Sheath: polyolefin compound; nominal diameter 4,0mm; colour black |
|
1x2xAWG22 | Assembly | |
Conductor: stranded bare copper wire 0,15mm; nom. 0,34mm² – AWG22; nominal diameter 0,75mm. Lay agree with UL 758 tab 5,9; conform to EN 13602 – ETP1, DIN 40500 E-Cu 58 ⇂ Insulation: polyolefin compound; nominal diameter 1,45mm ⇂ Core Identification: white – black ⇂ Assembly: two cores twisted to a pair ⇂ Screen: braid type; tin copper wire; nominal optical coverage 85% ⇂ Protective Tape: tape under and over screen |
4x21AWG + 1x(2x26AWG) + 1x(2x22AWG) stranded together around a central fibrous filler; if necessary other fillers could be used for a better roundness. | |
Screen | Protective Tape | |
Braid type; tin copper wire; nominal optical coverage 85% | Tape under and over total screen | |
Sheath | Electrical | |
Outer sheath: PUR (ether base), 90 ShA; diameter 10,0 ±0,30mm Colour: orange similar RAL 2003; conform to UL AWM Style 21223 |
Rating voltage: 1000 Vrms Test voltage C/C (AWG21): 2000 Vac Test voltage C/C (AWG22): 1000 Vac Test voltage C/C (AWG26): 500 Vac Electric resistance (AWG21): 39,9 Ω/Km (IEC 60344) Electric resistance (AWG22): 62,4 Ω/Km (IEC 60344) Electric resistance (AWG26): 145,8 Ω/Km (IEC 60344) Capacity (AWG26): 45 ±15 pF/m (800-1000Hz) Impedance (AWG26): 110 ±11 Ω |
|
Temperature | Bending Radius | |
Operating temperature range, fixed: -40 °C to +80 °C Operating temperature range, flex: -25 °C to +80 °C |
Bending radius, fixed: 5 x Ø Bending radius, flex: 7,5 x Ø Bending: up to 5 Mio |
|
Flame | Approval | |
UL Cable Flame Test; UL VW-1, CSA FT1; IEC 60332-1-2 | Oil-resistant: UL 758 UV-resistant: UL 1581 Halogen-free: CEI EN 60754-1 / VDE 0482-754-1 FCKW, Silicone and Pb free: yes |