SS2X2X0,18+5X0,50

Il prodotto non è attualmente in magazzino e non è disponibile.

SKU: SS2X2X0,18+5X0,50 Category:
2x2xAWG25 5xAWG21
Conductor: stranded tin copper wire 0,10mm (Class 6); nom. 0,18mm² – AWG25; nominal diameter 0,6mm; VDE 0295. Lay agree with UL 758 tab 5,9; conform to EN 13602 – ETP1, DIN 40500 E-Cu 58

Insulation: polyolefin; nominal diameter 1,1mm

Core Identification: white-brown – black-violet

Assembly: four cores twisted in two pairs
Conductor: Stranded tin copper wire 0,10mm (Class 6); nom. 0,50mm² – AWG21; nominal diameter 1,00mm; VDE 0295. Lay agree with UL 758 tab 5,9; conform to EN 13602 – ETP1, DIN 40500 E-Cu 58

Insulation: polyolefin; nominal diameter 1,5mm

Core Identification: grey – yellow – green – pink – blue
Assembly Screen
1x2xAWG25 + 5xAWG21 stranded together around a central pair 1x2xAWG25Braid type; tin copper wire; nominal optical coverage 85%
DW: tin copper wire 0,10mm; nom. 0,18mm² / AWG25; under braid screen
Protective Tape Sheath
Tape under and over screenOuter sheath: PUR (ether base), 90 ShA; diameter 7,70 ±0,2mm
Colour: green similar RAL 6018 (matt finish); conform to UL AWM Style 20233
Electrical Temperature
Operating voltage: 300 Vrms
Test voltage C/C: 1500 Vac
Conductor resistance (AWG25): 121 Ω/Km (IEC 60344)
Conductor resistance (AWG21): 41,9 Ω/Km (IEC 60344)
Operating temperature range, fixed: -40 °C to +80 °C
Operating temperature range, flex: -20 °C to +80 °C
Bending Radius Movement Data
Bending radius, fixed: 5 x Ø
Bending radius, flex: 10 x Ø
Speed: 220 m/min
Acceleration: 12 m/sec²
Bending cycles: 10 Mio (20 Mio bends)
FlameApproval
UL Cable flame test; CSA FT1; IEC 60332-1-2Oil-resistant: UL 758
UV-resistant: yes
Halogen-free: CEI EN 60754-1 / VDE 0482-754-1
Silicone, Pb, Cd, Hg, FCKW free: yes
Hydraulic fluid, coolant emulsifier, alkali: resistant to a large extent
Code

SS2X2X0,18+5X0,50

Cable Type

2 x 2 x 0,18 + 5 x 0,5

Ø mm

7,7

Tolerance

±0,20 mm