SS3X2X0,18+6X1

Il prodotto non è attualmente in magazzino e non è disponibile.

SKU: SS3X2X0,18+6X1 Category:
3x2xAWG25 6xAWG18
Conductor: stranded tin copper wire 0,10 (Class 6); nom. 0,18mm² – AWG25; nominal diameter 0,60mm; VDE 0295. Lay agree with UL 758 tab 5,9; conform to EN 13602 – ETP1, DIN 40500 E-Cu 58

Insulation: polyolefin; nominal diameter 1,1mm

Core Identification: white-red – red-black – white-black

Assembly: six cores twisted in three pairs with appropriate lay
Conductor: stranded tin copper wire 0,25mm (Class 5); nom. 1,0mm² – AWG18; nominal diameter 1,25mm; VDE 0295. Lay agree with UL 758 tab 5,9; conform to EN 13602 – ETP1, DIN 40500 E-Cu 58

Insulation: polyolefin; nominal diameter 1,5mm

Core Identification: black numbered from 1 to 3 + red numbered from 4 to 6
Assembly Screen
2x2xAWG25 + 6xAWG18 stranded together around a central pair 1x2xAWG25; some filler could be used for a better roundnessBraid type; tin copper wire; nominal optical coverage 85%
DW: stranded tin copper wire 0,1mm; 0,18mm² / 25AWG; under braid screen
Protective Tape Sheath
First: tape over total assembly
Second: tape over total screen
Outer sheath: PUR (ether base), 90 ShA; diameter 8,80 ±0,2mm
Colour: green; conform to UL Style 20233
Electrical Temperature
Rating voltage: 300 Vrms
Test voltage C/C: 1500 Vac
Electric resistance (AWG18): 21,6 Ω/Km (IEC 60344)
Electric resistance (AWG25): 121 Ω/Km (IEC 60344)
Operating temperature range, fixed: -40 °C to +80 °C
Operating temperature range, flex: -20 °C to +80 °C
Bending Radius Movement Data
Bending radius, fixed: 5 x Ø
Bending radius, flex: 10 x Ø
Speed: 220 m/min
Acceleration: 12 m/sec²
Bending cycles: 10 Mio (20 Mio bends)
Flame Approval
UL Cable Flame Test; CSA FT1; IEC 60332-1-2Oil-resistant: UL 758
UV-resistant: UL 1581
Halogen-free: CEI EN 60754-1 / VDE 0482-754-1
FCKW, Silicone and Pb free: yes
Code

SS3X2X0,18+6X1

Cable Type

3 x 2 x 0,18 + 6 x 1

Ø mm

8,8

Tolerance

±0,20 mm