SS4X2X0,14+4X0,50

Il prodotto non è attualmente in magazzino e non è disponibile.

SKU: SS4X2X0,14+4X0,50 Category:
4x2xAWG26 4xAWG21
Conductor: stranded tin copper wire 0,10mm; nom. 0,14mm² – AWG26; nominal diameter 0,50mm. Lay agree with UL 758 tab 5,9; conform to EN 13602 – ETP1, DIN 40500 E-Cu 58

Insulation: polyolefin compound; nominal diameter 0,95mm

Core Identification: grey-pink – violet-yellow – brown-green – red-black

Assembly: eight cores twisted in four pairs
Conductor: stranded tin copper wire 0,15mm; nom. 0,50mm² – AWG21; nominal diameter 0,95mm. Lay agree with UL 758 tab 5,9; conform to EN 13602 – ETP1, DIN 40500 E-Cu 58

Insulation: polyolefin compound; nominal diameter 1,55mm

Core Identification: white – blue – brown/green – white/green
Assembly Screen
4x2xAWG26 + 4xAWG21 stranded together around a central fillerBraid type; tin copper wire 0,10mm; nominal optical coverage 85%
Protective Tape Sheath
Tape under and over screenOuter sheath: PUR (ether base), 90 ShA; diameter 8,6 ± 0,2mm
Colour: green similar RAL 6018; conform to UL Style 20233
Electrical Temperature
Operating voltage: 300 Vrms
Test voltage C/C: 1500 Vac
Conductor resistance (AWG26): 152,6 Ω/Km (IEC 60344)
Conductor resistance (AWG21): 41,1 Ω/Km (IEC 60344)
Operating temperature range, fixed: -40 °C to +80 °C
Operating temperature range, flex: -20 °C to +80 °C
Bending Radius Movement Data
Bending radius, fixed: 5 x Ø
Bending radius, flex: 10 x Ø
Speed: 220 m/min
Acceleration: 12 m/sec²
Bending cycles: 10 Mio (20 Mio bends)
FlameApproval
UL Cable flame test; CSA FT1; IEC 60332-1Oil-resistant: UL 758
UV-resistant: yes
Halogen-free: CEI EN 60754-1 / VDE 0482-754-1
Silicone, Pb, Cd, Hg, FCKW free: yes
Hydraulic fluid, coolant emulsifier, alkali: resistant to a large extent
Code

SS4X2X0,14+4X0,50

Cable Type

4 x 2 x 0,14 + 4 x 0,5

Ø mm

8,6

Tolerance

±0,20 mm