Conductor | Insulation | |
Stranded bare copper wire 0,10mm (Class 6); nom. 0,34mm² – AWG22; nominal diameter 0,80mm; Cl.6 VDE 0295 Lay agree with UL 758 tab 5,9; conform to EN 13602 – ETP1, DIN 40500 E-Cu 58 |
Polyolefin; nominal diameter 1,27mm | |
Core Identification | Assembly | |
Colours acc. to DIN 47100 | Pair: cores twisted in pairs (white-brown – green-yellow) Total: two pairs stranded together; some fillers could be used for a better roundness |
|
Screen | Protective Tape | |
Braid type; tin copper wire; nominal optical coverage 85% | Tape under and over screen | |
Sheath | Electrical | |
Outer sheath: PUR (ether base); hardness 92 ShA; diameter 6,80 ±0,25mm Colour: green similar RAL 6018; conform to UL AWM Style 20233 |
Operating voltage: 300 Vrms Test voltage: 2000 Vac Conductor resistance: 65,3 Ω/Km (IEC60344) |
|
Temperature | Bending Radius | |
Operating temperature range, fixed: -40 °C to +80 °C Operating temperature range, flex: -25 °C to +80 °C |
Bending radius, fixed: 5 x Ø Bending radius, flex: 10 x Ø |
|
Flame | Movement Data | |
UL Cable flame test; CSA FT1; IEC 60332-1-2 | Speed: 300 m/min Acceleration: 10 m/sec² Bending cycles: up to 5 Mio (10 Mio Stroke) |
|
Approval | ||
Oil-resistant: UL 758 UV-resistant: yes Halogen-free: CEI EN 60754-1 / VDE 0482-754-1 Silicone, Pb, Cd, Hg, FCKW free: yes |