| Conductor | Insulation | |
| Bare copper (Class 6) Acc. to IEC 60228 / VDE 0295 | Polypropylene compound | |
| Core Identification | Assembly | |
| X (≤0,34mm²): acc. to DIN47100 X (≥0,50mm²): numbers G (≥0,50mm²): green/yellow + numbers | Conductors cabled together with optimal lay-length, fillers admitted | |
| Screen | Protective Tape | |
| Tinned copper braid; optical coverage approx 85% | Nonwovens tape over assembly and over screen | |
| Sheath | Electrical | |
| Outer sheath: PVC compound Colour: grey similar RAL 7001 | Nominal voltage (≤0,34mm²): 300 V Nominal voltage (≥0,50mm²): 1000 V Test voltage (≤0,34mm²): 2000 V Test voltage (≥0,50mm²): 4000 V Conductor resistance: max at 20 °C in acc. to IEC 60228 and VDE 0812 Insulation resistance: at 20 °C > 1 GΩxKm | |
| Temperature | Bending Radius | |
| Operating temperature range, fixed: -40 °C to +80 °C Operating temperature range, flex: -20 °C to +80 °C (avoid continuous use in chains with temperatures below 0 °C) | Bending radius, fixed: 5 x Ø Bending radius, flex: 7,5 x Ø (up to 5 Mio Bending cycles) | |
| Movement Data | Flame | |
| Speed: up to 180 m/min Acceleration: up to 20 m/sec² Length of chain: 10 m (orizontal only) Cycle number: 3.000.000 | IEC 60332-1-2 / UL 1581 VW-1 / CSA FT1 | |
| Approval | ||
| Oil-resistant: VDE 0473-811-404, UL 1581, IEC 60811-404 UV-resistant: yes |