| 3x2xAWG26 | 2xAWG22 | |
| Conductor: stranded bare copper wire; nom. 0,14mm² – AWG26/7; nominal diameter 0,48mm; Lay agree with UL 758 tab 5,9; conform to EN 13602 – ETP1, DIN 40500 E-Cu 58 ⇂ Insulation: polyolefin; nominal diameter 1,00mm ⇂ Core Identification: white-brown – green-yellow – grey-pink; acc. to DIN 47100 ⇂ Assembly: six cores twisted in three pairs with appropriate lay | Conductor: stranded bare copper wire; nom. 0,34mm² – AWG22/19; nominal diameter 0,75mm. Lay agree with UL 758 tab 5,9; conform to EN 13602 – ETP1, DIN 40500 E-Cu 58 ⇂ Insulation: polyolefin; nominal diameter 1,15mm ⇂ Core Identification: red – blue; conform to UL 758 | |
| Assembly | Screen | |
| 3x2xAWG26 + 2xAWG22 with appropriate lay; fibrous filler can be used for a better roundness | First: Al/PET tape (aluminium face outside); optical coverage 100% Second: braid type; tin copper wire 0,10mm; nominal optical coverage 85% | |
| Protective Tape | Sheath | |
| Tape over braid screen | Outer sheath: PUR (11Y), ether base; 90 ShA; diameter 6,80 ±0,20mm Colour: green similar RAL 6018 (matt finish); conform to UL AWM Style 20233 | |
| Electrical | Temperature | |
| Operating voltage: 300 V Test voltage: 2000 V x 1min Conductor resistance (AWG26): 150,3 Ω/Km (IEC 60344) Conductor resistance (AWG22): 60,6 Ω/Km (IEC 60344) Insulation resistance: ≥2 GΩxKm | Operating temperature range, fixed: -40 °C to +80 °C Operating temperature range, flex: -20 °C to +80 °C | |
| Bending Radius | Movement Data | |
| Bending radius, flex: 10 x Ø | Recommended speed: <200 m/min (up to 300 m/min) Recommended acceleration: <3 m/sec² (up to 30 m/sec²) | |
| Flame | Approval | |
| UL Cable flame test; CSA FT1; IEC 60332-1-2 | Oil-resistant: UL 758 UV-resistant: UL 1581 Halogen-free: CEI EN 60754-1 / VDE 0482-754-1 Microbe-resistant: yes Hydrolysis resistant: EN 50396 Hydraulic fluid, coolant emulsifier, alkali: resistant to a large extent Cable suitable for drag chain use |