| 1x2xAWG22 (Power) | 2x2xAWG24 (Data) | |
| Conductor: stranded tin copper wire; nom. 0,34mm² – AWG22; nominal diameter 0,80mm. Lay agree with UL 758 tab 5,9; conform to EN 13602 – ETP1, DIN 40500 E-Cu 58 ⇂ Insulation: PE compound; nominal diameter 1,03mm ⇂ Core Identification: back – red ⇂ Assembly: two cores twisted to a pair with fillers in gap | Conductor: stranded bare copper wire; nom. 0,25mm² – AWG24; nominal diameter 0,60mm. Lay agree with UL 758 tab 5,9; conform to EN 13602 – ETP1, DIN 40500 E-Cu 58 ⇂ Insulation: PE compound; nominal diameter 1,03mm ⇂ Core Identification: yellow-green – blue-pink ⇂ Assembly: four cores twisted into two pairs with fillers in gap | |
| Assembly | Screen | |
| 2x2x24AWG + 1x2x22AWG stranded together, some fillers could be used for a better roundness; lay according to UL 758 | St type: aluminium foil (Al/PET) overlapped (aluminium face outside); optical coverage 100% C type: braid type; tin copper wire 0,12mm; nominal optical coverage 85% St type: conductive tape (nonwovens/Al) overlapped on braid; optical coverage 100% | |
| Protective Tape | Sheath | |
| First: double nonwovens tape (TNT) over total assembly Second: nonwovens tape (TNT) under sheath | Outer sheath: PUR (ether base), 90 ShA; diameter 7,00 ±0,20mm; conform to UL Style 20236 Colour: green RAL 6018 | |
| Electrical | Temperature | |
| Operating voltage: 300 Vrms Test voltage (wire/wire/screen): 500 V x 1min (f=50Hz) Conductor resistance (AWG24): 97,5 Ω/Km (IEC 60344) Conductor resistance (AWG22): 56,4 Ω/Km (IEC 60344) Insulation resistance: ≥2 GΩxKm Nominal capacitance (AWG24): 50 nF/Km Nominal impedance (AWG24): 100 Ω Attenuation max (dB/100m): 35 dB Near-end crosstalk: min. 32 dB Return loss: min. 12 dB | Operating temperature range, fixed: -40 °C to +80 °C Operating temperature range, flex: -20 °C to +80 °C | |
| Bending Radius | Movement Data | |
| Bending radius, fixed: 4 x Ø Bending radius, flex: 7,5 x Ø | Speed: 300 m/min Acceleration: 50 m/sec² Torsion: ≤ ±30 °/m Bending cycles: 10 Mio (20 Mio stroke) | |
| Flame | Approval | |
| UL Cable flame test; CSA FT1; IEC 60332-1-2 | Oil-resistant: UL 758 UV-resistant: UL 1581 Halogen-free: CEI EN 60754-1 / VDE 0482-754-1 Silicone, Pb, Cd, Hg, FCKW free: yes Microbe-resistant: yes Hydrolysis-resistant: EN 50396 Hydraulic fluid, coolant emulsifier, alkali: resistant to a large extent |