BUSPROFINETPUR

This product is currently out of stock and unavailable.

SKU: BUSPROFINETPUR Category:
Conductor   Insulation
Stranded tin copper wire 0,15mm (Class 6 VDE0295); nom. 0,34mm² – AWG22; nominal diameter 0,75mm
Lay agree with UL 758 tab 5,9; conform to EN 13602 – ETP1, DIN 40500 E-Cu 58
Polyolefin compound; nominal diameter 1,45mm
Core Identification Assembly
Colour cores: yellow – blue – orange – white Cores stranded together around a central filler
Screen   Protective Tape
First: Al/PET tape (aluminum face outside), nominal optical coverage 100%
Second: braid type; tin copper wire, nominal optical coverage 80%
Tape over braid screen
Sheath   Electrical
Inner sheath: flame retardant compound; nominal diameter 4,30mm, colour natural
Outer sheath: PUR (ether base), hardness 92 ShA; Diameter 6,8 ±0,2mm
Colour: green similar RAL6018
Test voltage: 2000 Vac
Operating voltage: 300 Vrms
Cable suitable for installation in coexistence with energy cables with voltage rating up to 0,6/1 KV
Conductor resistance: 60,6 Ω/Km (IEC60344)
Insulation resistance @20°C: ≥ 500 MΩ x Km
Nominal impedance: 100 Ω
Nominal capacitance: 55 pF/m
Nominal capacitance (C/S): 105 pF/m
Temperature   Bending Radius
Operating temperature range, fixed: -40 °C to +80 °C
Operating temperature range, flex: -20 °C to +70 °C
Bending radius, fixed: 5 x Ø
Bending radius, flex: 7,5 x Ø
Movement Data   Flame
Speed: 300 m/min
Acceleration: 50 m/sec²
Torsion: ± 30°/m
UL Cable flame test; UL VW-1; CSA FT1; IEC 60332-1-2
Approval  
Oil-resistant: UL758
Halogen-free: CEI EN 60754-1 / VDE 0482-754-1
Silicone, Pb, Cd, Hg, FCKW free: yes

Accordance to:
– ProfiNET cabling and interconnection technology Guideline for ProfiNET (5.0 May 2021)
– ISO11801-2 §9.3.2.6 – Flexible cable Class D
– IEC 61156-6 – Work area wiring Cat.5e
– Suitable for Fast Connect technology
Code

BUSPROFINETPUR

Cable Type

2 x 2 x 0,34

Ø mm

6,8

Tolerance

±0,20 mm