| Conductor | Insulation | |
| Stranded bare copper wire (Class 6 VDE0295); 42×0,10mm (nom. 0,34mm² – AWG22); nominal diameter 0,80mm Lay agree with UL 758 tab 5,9; conform to EN 13602 – ETP1, DIN 40500 E-Cu 58 | Foam PE (with internal and external skin); hardness 61 ShD; diameter 1,75 ±0,10mm | |
| Core Identification | Assembly | |
| Colour cores: white – brown – green – yellow acc. to DIN47100 | Four cores stranded in star quad; some filler could be used for a better roundness | |
| Screen | Protective Tape | |
| First: Al/PET tape wrapped over total assembly (Aluminium face outside); optical coverage 100% Second: braid type; tin copper wire 0,10mm; nominal optical coverage 80% Drain wire: stranded tin copper wire 0,25mm² (AWG24); DW under braid screen | First: PET tape wrapped over assembly Second: nonwovens tape (TNT) over total screen | |
| Sheath | Electrical | |
| Outer sheath: PUR, hardness 92 ShA; diameter 6,70 ±0,20mm; conform to UL 20236 Colour: violet similar RAL4001 | Test voltage: 1000 V x 1min Operating voltage: 30 V Conductor resistance: 61,6 Ω/Km Impedance: 120 Ω ± 10% Nominal capacitance @1KHz: 50 pF/m | |
| Temperature | Bending Radius | |
| Operating temperature range, fixed: -40 °C to +80 °C Operating temperature range, flex: -30 °C to +80 °C | Bending radius, fixed: 10 x Ø Bending radius, flex: 15 x Ø | |
| Movement Data | Flame | |
| Speed: up to 200 m/min Acceleration: up to 10 m/sec² Torsion: ±30° | UL Cable Flame test; CSA FT1; IEC 60332-1; ISO6722 | |
| Approval | ||
| Oil-resistant: UL758; ISO6722 UV-resistant: UL1581 / 2556– 300h Halogen-free: CEI EN 60754-1 / VDE 0482-754-1 Silicone, Pb, FCKW free: yes |