2xAWG14 | (2xAWG24)C | |
Conductor: stranded bare copper wire; nom. 2,5mm² – AWG14; nominal diameter 2,1mm. Lay agree with UL 758 tab 5,9; conform to EN 13602 – ETP1, DIN 40500 E-Cu 58 ⇂ Insulation: polyolefin compound; nominal diameter 3mm; Core Identification: black numbered 1 and 2 | Conductor: stranded bare copper wire; nom. 0,25mm² – AWG24; nominal diameter 0,62mm. Lay agree with UL 758 tab 5,9; conform to EN 13602 – ETP1, DIN 40500 E-Cu 58 ⇂ Insulation: polyolefin compound; nominal diameter 2mm ⇂ Core Identification: white – brown ⇂ Assembly: two cores twisted together with filler in gap ⇂ Screen: braid type; tin copper wire; nominal optical coverage 85% ⇂ Protective Tape: tape under and over screen | |
Assembly | Protective Tape | |
2xAWG14 + (2xAWG24)C stranded together around central filler; some fillers could be used for a better roundness | Tape over total assembly | |
Sheath | Electrical | |
Outer sheath: PUR (ether base), hardness 90 ShA; diameter 10,4 ±0,3mm; conform to UL AWM Style 21223 Colour: black similar RAL9005 | Test voltage C/C: 4000 Vac Operating voltage: 1000 Vrms Conductor resistance (AWG14): 8,3 Ω/Km (IEC60344) | |
Electrical (AWG24) | Temperature | |
Test voltage (C/C): 1000 Vac Test voltage (C/S): 500 Vac Operating voltage: 50 Vrms Conductor resistance: 85,8 Ω/Km (IEC 60344) Nominal capacitance @1KHz: 40 pF/m Nominal characteristic impedance: 120 Ω | Operating temperature range, fixed: -40 °C to +80 °C Operating temperature range, flex: -30 °C to +80 °C | |
Bending Radius | Movement Data | |
Bending radius, fixed: 5 x Ø Bending radius, flex: 10 x Ø | Speed: 300 m/min Acceleration: 50 m/sec² | |
Flame | Approval | |
UL Cable flame test; CSA FT1; IEC 60332-1-2 | Oil-resistant: UL758 Halogen-free: CEI EN 60754-1 / VDE 0482-754-1 Silicone, Pb, Cd, Hg, FCKW free: yes |